Zetec Topaz 64 Channel Phased Array Instrument
Driven by industrially proven UltraVision Software
TOPAZ64 includes UltraVision Touch software onboard. This powerful, yet easy to use software controls the acquisition of Phased Array UT signals, displays real-time images and provides online and offline data analysis. UltraVision offers advanced features for TOPAZ64 designed to improve Phased Array UT inspections, including real-time high resolution TFM, and post-processed TFM from recorded elementary A-Scans. TOPAZ64 and UltraVision Software support 2D matrix arrays in pulse echo, pitch & catch or multiprobe configurations without the need for any external software.
Featuring the latest in UT including Total Focusing Method (TFM)
TOPAZ64 is packed with smart features to handle all UT inspections in one portable package. It features the latest technologies in ultrasound including:
- Code Compliant 32 or 64 Channel Phased Array UT
- High Resolution Full Matrix Capture (FMC) with up to 64 elements
- Real-Time Total Focusing Method (TFM) up to 1M Data Points per Frame
- Time of Flight Diffraction (TOFD)
SMART FEATURES
Zetec Topaz 64 is packed with features for an inspection advantage
The highly intelligent TOPAZ64 continues this tradition with many features unmatched in its class.
Zetec Topaz64 64 Channel Phased Array Instrument SPECIFICATIONS
Size (H × W × D) | 343 × 278 × 158 mm (13.5 × 10.9 × 6.2 in) |
Weight (including one battery) | 9.1kg (20.0 lb) |
Multi-Touch Display | 12.1 in. wide, 1024 x 768 pixels |
Air Intake | No |
Battery Operation | Yes |
Phased Array Connector | ZPAC |
Phased Array Channels | 32/128PR; 64/64PR or 64/128PR |
UT Channels | 2 P/E or 2 P/C |
Amplitude Resolution | 16-bits |
Measurement Gates | 4 + 1 synchronization gate (peak, crossing, autocrossing) |
Data Interfaces | Ethernet 1000 Base-T; 1 x USB 3.0; 3 x USB 2.0 |
Maximum PRF | < 40 kHz |
Data Compression | 1, 2, 4, 8, 16 |
Max. Applied Voltage (50 ohms) | 150Vpp PA UT (Bipolar) /75V (Unipolar) / 200V UT |
Bandwidth (-3 dB) | 0.5 to 18 MHz PA; 0.5 to 25 MHz UT |
Rectification | Digital |
Filtering | Analog / Digital (FIR) |
Smoothing | Digital |
Self-Check | Yes |
Automated Probe Detection | Yes (with Zetec probe ID chip) |
Automated Scanner Detection | Yes (with Zetec probe ID chip) |
# Focal Laws | 1024 with unlimited groups |
TFM Frame Size | Up to 1M points |
TFM Frame Rate | Up to 110 Hz (65k points per frame resolution) |
Maximum Number of Samples | 16,384 |
Maximum Data File Size | 2 GB; Unlimited for raw A-Scan data |
Encoder Interfaces | 3 quadrature-type |
Onboard Software | UltraVision Touch embedded |
Serves as Protection Key | License for UltraVision Touch |
Data Acquisition & Analysis (for remote data acquisition or off line postprocessing | UltraVision Touch; UltraVision 3 |
Embedded Hard Drive | 256 GB SSD |
Video Output | HDMI |
Instrument Calibration | Compliant with ISO 18563-1 / EN 12668-1 |
Voltage | 100 to 240 VAC |
Frequency | 50 or 60 Hz |
Maximum Power | 100 VA |
Operating Temperature Range | -10°C to 45°C (14°F to 113°F) |
Storage Temperature Range | -40°C to 70°C (-40°F to 158°F) |
Relative Humidity | 80% non-condensing |
Ingress Protection Rating | Designed for IP66 |